Description
The PQ3450-2 is a 200 Amp Datalogging Power Analyzer (up to 30,000 sets of measurements). Large dot-matrix, sun-readable, numerical, backlit LCD with easy-to-use onscreen menu. Full system analysis with up to 35 parameters. Includes 200 Amp Current Clamps; Optional 1200 Amp Current Clamps or 3000 Amp Flexible Current Probes. Adjustable Current Transformer CT (1 to 600) and Potential Transformer PT (1 to 1000) ratio for high power distribution systems. Log up to 30,000 reading on a removable SD memory card in Excel® format. Wide sampling rate range (2 seconds to 2 hours). Built-in Clock and Calendar. Complete with 4 voltage leads with alligator clips, 8 AA batteries, SD card, 100-240V AC adapter and case.
Specifications | Range | Basic Accuracy |
---|---|---|
AC Voltage (True rms) | 600.0V | ±(0.5%rdg) |
AC Current | 3000A | ±(0.5%rdg) |
Active Power (MW) | 9.999MW | ±(1.0%rdg) |
Apparent Power (MVA) | 9.999MVA | ±(1.0%rdg) |
Reactive Power (MVAR) | 9.999MVAR | ±(1.0%rdg) |
Power Factor | 0.00 to 1.00 | ±0.04 |
Frequency Range | 45Hz to 65Hz | ±0.1Hz |
Phase | -180° to +180.0° | ±1° |
Current Clamp input | 200mV, 300mV, 500mV | ±(0.5%rdg) |
1V, 2V, 3V; user-selectable | ||
Active Power Energy (MWH) | 0.0kWh to 9.999MWH | ±(2.0%rdg) |
Apparent Power Energy (MVAH) | 0.0KVAh to 9.999MVAH | ±(2.0%rdg) |
Reactive Power Energy (MVARH) | 0.0kVARh to 9.999MVARH | ±(2.0%rdg) |
Datalogging | 30,000 readings (2GB SD memory Card) | |
Dimensions | 8.86 x 4.92 x 2.52″ (225 x 125 x 64mm) | |
Weight | Meter: 2.2lbs (1010g) |