FLUKE

Fluke Norma 4000: Power Analyzers

Fluke

Download       

       00961 1 894 243

$9,992.00

Description

Reliable, highly accurate measurements for the test and development of power electronics

The compact Fluke Norma Series Power Analyzers provide the latest measurement technology to assist engineers with the development and testing of motors, inverters, lighting, power supplies, transformers and automotive components.

Based on a patented, high-bandwidth architecture, the instruments deliver high-precision measurements of single or three-phase current and voltage, harmonics analysis, Fast Fourier Transformation (FFT) analysis, as well as calculations of power and other derived values.

The Series consists of the Fluke Norma 4000 4000 Three-Phase Power Analyzer and the Fluke Norma 5000 Six-Phase Power Analyzer. These rugged, high-precision analyzers provide unmatched price performance for easy and reliable use in the field, or as a bench unit in laboratories and on test benches.

Applications:

  • Electric motors and inverter drive systems – Through detailed spectrum analysis and dynamic torque calculation capabilities, switching losses caused by the inverter are accurately measured, and a thorough evaluation is made of torque transients and harmonics at higher frequencies.
  • Inverter drive system – Simultaneous measurement of all electrical and mechanical power parameters in the same time window enables users to observe the influence one component has on another, or on the whole system.
  • Lighting systems – A wide bandwidth of up to 10 MHz and a high sampling rate up to 1 MHz provide detailed signal analysis at ballast outputs. A unique shunt technique enables power measurements at very high frequencies. Simultaneous measurement of input and output power provides instant calculation of ballast losses.
  • Transformers – Synchronous six-phase power measurements enable highly accurate efficiency and loss calculations of large power transformers even at very low power factors. Synchronous multiphase resistance measurements of transformer coils are also possible.
  • Automotive – Synchronous electrical input and mechanical output measurements provide complete data on the efficiency and losses of individual components as well as the whole drive system.

Specifications:

  Fluke Norma 4000 Fluke Norma 5000
Number of Phases 1 or 3 3, 4 or 6
Weight Approx. 5 kg Approx. 7 kg
Size (HxWxD) 15 cm x 23.7 cm x 31.5 cm 15 cm x 44.7 cm x 31.5 cm
On-board Printer No Yes (optional)
Display Color, 5.7“ / 144 mm – 320 x 240 pixel
Bandwidth dc to 3 MHz or dc to 10MHz depending on input module
Basic Accuracy 0.2%, 0.1% or 0.03% depending on input modules
Sampling Rate 0.33 MHz or 1 MHz depending on input modules
Voltage Input Range 0.3 V to 1000 V
Current Input Range (direct, not via shunt) 0.03 mA – 20 A depending on input module
Memory for Configurations 4 MB
Memory for Settings 0.5 MB
Fast Fourier Transformation (FFT) To the 40th harmonic
RS232 Interface Standard
PI1 Process Interface (8 analog/impulse inputs and 4 analog outputs) Optional
IEEE 488.2 /GPIB Interface (1 MBit/s Ethernet / 10 MBit/s or 100 Mbit/s) Optional
Fluke NormaView PC Software (for data download, analysis & report writing) Standard

Additional information

Brands