SONEL

Sonel MIC-10K1: Insulation Resistance Meter

Download           

       00961 1 894 243

Description

Insulation resistance measurement:
· up to 40 TΩ for MIC-10k,
· up to 20 TΩ for MIC-5050,
– measurement voltage any in the range of:
· 50…5000 V for MIC-5050 (50…1000 V at 10 V and 1…5 kV at 25 V),
· 50…10000 V for MIC-10k1 (50…1000 V at 10 V and 1…10 kV at 25 V),
– continuous indication of measured insulation resistance or leakage current,
– automatic discharge of measured object capacitance voltage after the end of insulation resistance measurement,
– acoustic signaling of 5 seconds intervals to facilitate capturing time characteristics,
– adjustable measuring time to 99’59’’,
– metered T , T and T test times for measuring one or two absorption coefficients from the range of 1…600 s, 1 2 3
– polarization index (PI), absorption coefficients Ab1, Ab2 and dielectric absorption ratio (DAR) measurement,
– indication of actual test voltage during measurement,
– 1.2 mA, 3 mA and 5 mA test current,
– insulation resistance measurement using two- or three-wire method,
– measurements with test leads up to 20 m…
– protection against measuring live objects,
– automatic measurement of multiple core cables with the additional AutoISO-5000 adapter (for MIC-10k1 max. voltage 5 kV)
– measurement of capacitance during the measurement of R . ISO
– measurement of temperature (with additional probe – WASONT1),
– step voltage insulation resistance measurement (SV),
– Dielectric Discharge calculation (DD),
– location of damage (burnout),

Additional information

Brands
Labels